Technical features and best practice of using transit-time flow for intraoperative bypass grafts assessment in variable clinical scenarios
Authors:
Company: Bakoulev National Medical Research Center for Cardiovascular Surgery, Moscow, Russian Federation
For correspondence: Sign in or register.
Type: Reviews
DOI:
For citation: Sigaev I.Yu., Keren M.A., Kazaryan A.V., Starostin M.V., Nazarov A.A., Morchadze B.D. Technical features and best practice of using transit-time flow for intraoperative bypass grafts assessment in variable clinical scenarios. Creative Cardiology. 2023; 17 (1): 25–33 (in Russ.). DOI: 10.24022/1997-3187-2023-17-1-25-33
Received / Accepted: 30.01.2023 / 29.03.2023
Abstract
Early graft dysfunction during coronary bypass surgery (CABG) is associated with serious clinical consequences, such as acute ischemia or myocardial infarction, which significantly worsens the patient's prognosis. Effective methods of assessing the quality of coronary grafts are important to achieve optimal results of CABG. Preferably, these methods should be available and applied directly during the operation in order to be able to eliminate a technical error. Transit time flowmetry (TTFM) is the most common intraoperative method of graft function assessment. TTFM is technically simple in execution and convenient for making clinical decisions. However, the correct interpretation of the obtained TTFM results is the subject of controversy due to the lack of generally accepted thresholds indicating graft dysfunction. This article presents the practice of optimal use of TTFM in order to identify graft dysfunction, as well as our own experience of using TTFM with a focus on various clinical scenarios accompanied by ambiguous changes in TTFM indicators. Also, the results of the consensus of experts on the problem of intraoperative application of TTFM in performing CABG are presented, which is of great importance for optimizing postoperative outcomes and improving the long-term prognosis.References
- Kieser T.M., Taggart D.P. The use of intraoperative graft assessment in guiding graft revision. Ann. Cardiothorac. Surg. 2018; 7: 652–62. DOI: 10.21037/acs.2018.07.06
- 2018 ESC/EACTS guidelines on myocardial revascularization. Russian Journal of Cardiology. 2019; 8: 151–226 (in Russ.). DOI: 10.15829/1560-4071-2019-8-151-226
- Amin S., Pinho-Gomes A.-C., Taggart D.P. Relationship of intraoperative transit time flowmetry findings to angiographic graft patency at follow-up. Ann. Thorac. Surg. 2016; 101 (5): 1996–2006. DOI: 10.1016/j.athoracsur.2015.10
- Shevchenko Yu.L., Zaichuk R., Borshchev G.G., Zemlyanov A.V., Ulbashev D.S. Transit time flowmetry for intraoperative bypass graft flow measurement. Bulletin of the N.I. Pirogov National Medical and Surgical Center. 2019; 14 (3): 98–103 (in Russ.). DOI: 10.25881/BPNMSC.2019.74.65.020
- Amin S., Werner R.S., Madsen P.L., Krasopoulos G., Taggart D.P. Intraoperative bypass graft flow measurement with transit time flowmetry: a clinical assessment. Ann. Thorac. Surg. 2018; 106: 532–8. DOI: 10.1016/j.athoracsur.2018.02.067
- Honda K., Okamura Y., Nishimura Y., Uchita S., Yuzaki M., Kaneko M. et al. Graft flow assessment using a transit time flow meter in fractional flow reserve-guided coronary artery bypass surgery. J. Thorac. Cardiovasc. Surg. 2015; 149: 1622–8. DOI: 10.1016/j.jtcvs.2015.02.050
- Lehnert P., Moller C.H., Damgaard S., Gerds T.A., Steinbruchel D.A. Transit-time flow measurement as a predictor of coronary bypass graft failure at one year angiographic follow-up. J. Card. Surg. 2015; 30: 47–52. DOI: 10.1111/jocs.12471
- Quin J., Lucke J., Hattler B., Gupta S., Baltz J., Bishawi M. et al. Surgeon judgment and utility of transit time flow probes in coronary artery bypass grafting surgery. JAMA Surg. 2014; 149 (11): 1182–7. DOI: 10.1001/jamasurg.2014.1891
- Une D., Deb S., Chikazawa G., Kommaraju K., Tsuneyoshi H., Karkhanis R. et al. Cut-off values for transit time flowmetry: are the revision criteria appropriate? J. Card. Surg. 2013; J (1): 3–7. DOI: 10.1111/jocs.12036
- Handa T., Orihashi K., Nishimori H., Fukutomi T., Yamamoto M., Kondo N. Maximal blood flow acceleration analysis in the early diastolic phase for in situ internal thoracic artery bypass grafts: a new transit-time flow measurement predictor of graft failure following coronary artery bypass grafting. Inter. CardioVasc. Thorac. Surg. 2015; 20: 449–57. DOI: 10.1093/icvts/ivu448
- Sigaev I.Yu., Keren M.A., Slivneva I.V., Shonia Z.D., Marapov D.I. The algorithm for using transit-time flow measurement and high-resolution epicardial ultrasound for intraoperative grafts assessment during coronary artery bypass surgery. Kardiologiia. 2022; 62 (6): 3–10 (in Russ.). DOI: 10.18087/cardio.2022.8.n1823
- Jokinen J.J., Werkkala K., Vainikka T., Perakyla T., Simpanen J., Ihlberg L. Clinical value of intraoperative transit-time flow measurement for coronary artery bypass grafting: a prospective angiography-controlled study. Eur. J. Cardiothorac. Surg. 2011; 39: 918–23. DOI: 10.1016/j.ejcts.2010.10.006
- Kieser T.M., Rose S., Kowalewski R., Belenkie I. Transit-time flow predicts outcomes in coronary artery bypass graft patients: a series of 1000 consecutive arterial grafts. Eur. J. Cardiothorac. Surg. 2010; 38: 155–62. DOI: 10.1016/j.ejcts.2010.01.026
- Singh S.K., Desai N.D., Chikazawa G., Tsuneyoshi H., Vincent J., Zagorski B.M. The Graft Imaging to Improve Patency (GRIIP) clinical trial results. J. Thorac. Cardiovasc. Surg. 2010; 139: 294–301. DOI: 10.1016/j.jtcvs.2009.09.048
- Sigaev I.Yu., Keren M.A., Shonia Z.D. The possibilities of ultrasonic flowmetry in combination with epicardial ultrasound scanning for a comprehensive assessment of the functional state of conduits during coronary bypass surgery. Thoracic and cardiovascular surgery. 2021; 63 (2): 133–9 (in Russ.). DOI: 10.24022/0236-2791-2021-63-2-133-139
- Тaggart D.P., Thuijs D.J.F.M., Di Giammarco G., Puskas J.D., Wendt D., Trachiotis G.D. et al. Intraoperative transit-time flow measurement and highfrequency ultrasound assessment in coronary artery bypass grafting. J. Thorac. Cardiovasc. Surg. 2020; 159: 1283–92.e2. DOI: 10.1016/j.jtcvs.2019.05.087
- Di Giammarco G., Canosa C., Foschi M., Rabozzi R., Marinelli D., Masuyama S. et al. Intraoperative graftverification in coronary surgery: increased diagnostic accuracy adding high-resolution epicardial ultrasonography to transit-time flow measurement. Eur. J. Cardiothorac. Surg. 2014; 45: e41–e45. DOI: 10.1093/ejcts/ezt580
- Haaverstad R., Vitale N., Tjomsland O., Tromsdal A., Torp H., Samstad S.O. Intraoperative color doppler ultrasound assessment of LIMA-to-LAD anastomoses in off-pump coronary artery bypass grafting. Ann. Thorac. Surg. 2002; 74 (4): S1390–4. DOI: 10.1016/s0003-4975(02)04058-4
- Andreasen J., Nohr D., Jorgensen A.S. A case report on epicardial ultrasonography of coronary anastomoses using a stabilizing device without the use of ultrasound gel. J. Cardiothorac. Surg. 2019; 13; 14 (1): 59. DOI: 10.1186/s13019-019-0882-2
- Gaudino M., Sandner S., Di Giammarco G., Di Franco A., Arai H., Asai T. et al. The use of intraoperative transit time flow measurement for coronary artery bypass surgery: systematic review of the evidence and expert opinion statements. Circulation. 2021; 144: 1160–71. DOI: 10.1161/CIRCULATIONAHA.121.0543112021
- Leong D.K., Ashok V., Nishkantha A., Shan Y.H., Sim E.K. Transit-time flow measurement is essential in coronary artery bypass grafting. Ann. Thorac. Surg. 2005; 79: 854–77. DOI: 10.1016/j.athoracsur.2004.06.010
About Authors
- Igor Yu. Sigaev, Dr. Med. Sci., Professor, Head of the Department; ORCID
- Milena A. Keren, Dr. Med. Sci., Senior Researcher; ORCID
- Artak V. Kazaryan, Dr. Med. Sci., Senior Researcher; ORCID
- Maxim V. Starostin, Cand. Med. Sci., Senior Researcher; ORCID
- Afanasy A. Nazarov, Cand. Med. Sci., Cardiovascular Surgeon; ORCID
- Beka D. Morchadze, Cand. Med. Sci., Researcher, Cardiovascular Surgeon; ORCID